Consumer Reviews of Triangle Tube boilers - FurnaceCompare.com

Ok I see alot of bad reviews here on these boilers I am a gas fitter for 10 years and I have put in well over 200 Triangle Tubes and plus every other make and model out there I don't sell or make money off of any boiler myself. I am a installer/ service tech for my company and Triangle Tube is the best boiler on the market for service.

Learn More

TRIANGLETUBE PRESTIGE SERVICE TECHNICIAN MANUAL Pdf

Page 26 Inspect the gas valve wiring harness and gas valve for a short circuit - Repair short circuit Reset the boiler control module and retry ignition sequence and boiler opera- tion. If problem continues, contact Triangle Tube Technical support for addi- tional assistance. Page 27 Internal Failure E- 60 Reset the boiler control module and

Learn More

Triangle Tube Prestige Boilers - SupplyHouse.com

The Prestige boiler features a uniquely designed stainless steel heat exchanger and offers 95% efficiency. The Prestige has the capability to modulate the firing rate to 25% of its rated input and is available in 5 sizes; a 60, 110 Stand Alone, 175, 250 and 399. Triangle Tube Prestige Boilers. 8

Learn More

IBC boiler SL20-115G2 delayed ignition Heating Help: The

Not sure about your boiler, but the Triangle Tube boiler has a gasket on the top plate that the burner mounts to that is about 5/8" thick or so. It is under the top plate. The ignitor goes through this gasket. The gasket just has a straight through hole cut in it for the ignitor to go through.

Learn More

Triangle Tube/Prestige Boiler--Rough Ignition Issues

Aug 08, 2011· Triangle Tube Technical Support noticed an increase of rough/failed ignitions during the past heating season on Prestige boilers. These intermittent ignition problems predominately occurred on PS60/PS110 and PE110 propane applications and to a much lower extent on its NG models, typically within 4 to 8 weeks after initial installation. Due

Learn More

PLANT EQUIPMENT 4 Flashcards | Quizlet

PLANT EQUIPMENT 4. The damper in a process furnace controls the amount of combustion air and excess oxygen in the burners.

Learn More

Triangle Tube - hvac-talk.com

Jan 26, 2016· A wall hung condensing boiler is not a "Do it yourself project". I have been installing these boilers since 2006 with no problems. When changing over from a cast iron chimney vented boiler the savings is in the 30 percent range. Triangle Tube in my opinion has the best heat exchanger in the industry and are whisper quiet.

Learn More

Boiler Service Vancouver - YouTube

Jan 18, 2016· Boilers have a large amount of vital components that really must be properly maintained. gas valve combustion fans, ignitions, seals as well as other elements all can be inspected during

Learn More

How Combustion Is Affected By Cold Oil And Air | Beckett Corp.

How Combustion Is Affected By Cold Oil And Air. with direct outside combustion air intake, excessive combustion air at the time of burner set-up may lead to ignition or retention problems in cold weather. Finally, always use test instruments. Use a draft gauge, pump pressure gauge, CO/O analyzer, and smoke tester to make adjustments

Learn More

Efficiency on a large scale Oil and Gas Fired Water Tube

Oil and Gas Fired Water Tube Packaged Boilers. SZS-Oil and Gas Fired Water Tube Package Boilers | 3 Cumulative record of total number of ignitions as well as operating times of fan, water pump, and burner Automatic rendering of curves for pressure, temperature, and other parameters

Learn More

How Combustion Is Affected By Cold Oil And Air | Beckett Corp.

How Combustion Is Affected By Cold Oil And Air. with direct outside combustion air intake, excessive combustion air at the time of burner set-up may lead to ignition or retention problems in cold weather. Finally, always use test instruments. Use a draft gauge, pump pressure gauge, CO/O analyzer, and smoke tester to make adjustments

Learn More

Triangle Tube Boilers - eComfort

Triangle Tube Boilers. Triangle Tube CC 105 - 94K BTU - 93.5% AFUE - Combi Gas Boiler - Direct Vent Wall Mounted, Condensing Boiler with Modulating Gas Valve. Ships Packaged. Ratings: 106K BTU Gross Input, 94K BTU DOE Capacity, 82K BTU Net IBR Capacity. Includes Circulator.

Learn More

Coal-Fired Boiler - an overview | ScienceDirect Topics

High-temperature corrosion may also occur, particularly at metal temperatures above 640°C. In coal-fired installations, high-sulphur coals containing an appreciable amount of chlorine give the most severe corrosion problems. Tube temperatures should be kept below 560°C in

Learn More

FAQ's for PT Boiler - FAQ - Triangle Tube - acv.com

FAQ's for PT Boiler FAQs for Contractors: This information is intended for contractors, installers, and engineers only! If you are NOT a qualified heating professional and attempt to apply this information to make repairs yourself, your warranty will be voided.

Learn More

7 Most Common Boiler Problems - Allen's Tri-State

Expansion tank problems. To manage the amount of pressure in the system, most boilers have an expansion tank. The tank can take in excessive pressure and release it without causing issues in the system. If the bladder within the expansion tank begins to fail, it can cause pressure changes in the boiler, signaled by banging pipes or failing joints.

Learn More

Best Chemicals for Clean Steam Boilers - Steam Boiler Tips

Calculate the amount of initial acid to use to get a 1-5% concentration of Chardons Scalzo in the boiler. Use only Scalzo to prevent excessive steel corrosion while the cleaning is taking place. Fill the boiler to capacity with water. Immediately add the Scalzo followed by a small amount of Chardons CTA-800 (4 oz per 1000 gallons).

Learn More

Triangle Tube Boiler Reviews & Consumer Reports 2018

We paid over $5,000 for this boiler almost three years ago and it has broken down several times already. We were out of heat and hot two times last winter for over a week each times. With a newborn in the house we were forced to stay in a motel for the whole time.: 2/5Top 54 Reviews and Complaints about Triangle Tubehttps:// Tube Prestige Solo 110 with domestic hot water system: Nothing but problems - my worst homeowner purchase. Installed in 2010, $8k for the boiler, another $3k for the hot water part.: 1.6/5TriangleTube Boiler Ingitor Keeps Getting Dirty - Handyman https://handymanwire.com/ubbthreads/ubbthreads.php/On these high efficiency boilers the tech should not only be testing fuel pressures but also doing a combustion test with a digital analyzer. Problems that can cause ignitor/flame sensor rotting: - moisture in fuel - incorrect fuel/air mix - plugging of the fire side exchanger the analyzer would be the first best diagnosing tool.

Learn More

INTRODUCTION TO BOILER - 123seminarsonly.com

INTRODUCTION TO BOILER Fire tube boilers 2. Water tube boilers 1. Fire tube boilers : Fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal used to extract large amount

Learn More

4 Different Designs of the Fire Tube Boiler: Which Is Best

Dec 02, 2016· 3. Scotch Fire Tube Boiler Design. The scotch fire tube boiler design is most commonly referred to as the scotch marine boiler. With this design, the furnace is a big diameter tube located inside of the boiler. The furnace and boiler are circumferenced by water. Some of the larger, older scotch boilers would have two or even three different

Learn More

Coal-Fired Boiler - an overview | ScienceDirect Topics

Coal-fired boilers are mainly operated at either subcritical or supercritical conditions. From a thermo-physics perspective, two phase mixtures of water and steam are replaced by a single supercritical fluid when the boiler pressure increases above the critical pressure of 22.12 MPa and the corresponding saturation temperature of 374 °C (Shen and Cheng, 2004).

Learn More

Troubleshooting an Intermittent Pilot Ignition System

Intermittent pilot lights ignite only during heating cycles. This design is more energy efficient than other pilot light designs and reduces the chances of a gas leak, but intermittent pilots arent without problems. Heres a quick look at commonly encountered issues with intermittent designs and some tips

Learn More

How Combustion Is Affected By Cold Oil And Air | Beckett Corp.

Cold oil and cold combustion air together can cause problems. The heavy, cold oil droplets are being carried away from the burner head by an excessive amount of cold excess oxygen. The increase in oxygen can be offset by the increase in flow rate of cold oil, but cold oil is usually the predominant factor.

Learn More

Triangle Tube Boilers - eComfort

Triangle Tube Boilers. Triangle Tube CC 105 - 94K BTU - 93.5% AFUE - Combi Gas Boiler - Direct Vent Wall Mounted, Condensing Boiler with Modulating Gas Valve. Ships Packaged. Ratings: 106K BTU Gross Input, 94K BTU DOE Capacity, 82K BTU Net IBR Capacity. Includes Circulator.

Learn More

Boiler Light off leads to Explosion - combustionsafety.com

Jun 26, 2018· Three separate industrial water tube boilers experienced fire-side explosions with boilers with a capacity of 20,000 to 40,000 pph and operated at 90 to 100 psig pressure. The explosions destroyed one boiler and damaged three others, fortunately no injuries were reported. The incidents came after the three boilers experienced trouble lighting-up,

Learn More

1.2 Anthracite Coal Combustion - US EPA

Typically coal rank increases as the amount of fixed carbon increases and the amount of volatile matter decreases. Anthracite coal is a high-ranking coal with more fixed carbon and less volatile matter than bituminous, subbituminous, or lignite varieties. Anthracite

Learn More